The features on this page require a GENESIS64 Advanced license and are not available with GENESIS64 Basic SCADA . |
This topic is a continuation of the process described in the Connecting to Open Databases topic. Follow these steps to establish an Oracle OLEDB database connection.
Note: If you previously created a connection in ReportWorX or BridgeWorX, you can re-use that connection here. |
To Connect to an Oracle OLEDB Database:
Open the Workbench. Expand your project folder, then the Data Connectivity node, then the Databases node.
Right-click the Generic OLEDB Connections node then click on Add Oracle OLEDB Connection, as shown below.
Add Oracle OLEDB Connection in Project Explorer
-OR-
Select the Generic OLEDB Connections node, then click on the Add Oracle OLEDB Connection button, shown below, in the Edit section of the Home ribbon in the Workbench.
Add Oracle OLEDB Connection Button
Oracle OLEDB Connection Properties
Enter a Description in the text entry field.
In Connection String, you can click on the Configure Connection link, which will open the Oracle OLEDB Connection String window, similar to the one shown below. Once you have entered the requested info, click OK to return to the connection properties.
Connection String Window
The Test Connection link allows you to check the connection parameters for possible errors.
Enter a Timeout (in seconds) for the ODBC Connection in the text entry field. "0" signifies no timeout.
Click Apply to save your changes and Close to exit from the connection properties.
See Also:
Creating a Database Connection