Dialogic Configuration Settings

Users and OEMs can customize the use of their Dialogic add-in phone cards. These settings are added to the ICOSETUP.INI file found in the %SystemRoot%/Documents and Settings/All Users/Application Data/ICONICS. The table below lists all of these configuration settings.

 

CA_NBRDNA

Number of Rings Before Detecting No Answer: The number of single or double rings to wait before returning a "no answer." (CA: Basic only)

Length: 1. Default: 4. Units: rings

CA_STDELY

Start Delay: The delay after dialing has been completed and before starting analysis for Cadence Detection, Frequency Detection, and Positive Voice Detection. (CA).

Length: 2. Default: 25. Units: 10 ms.

CA_CNOSIG

Continuous No Signal: The maximum time of silence (no signal) allowed immediately after Cadence Detection begins. If exceeded, a "no ringback" is returned. (CA)

Length: 2. Default: 4000. Units: 10 ms

CA_LCDLY

 Loop Current Delay: The delay after dialing has been completed and before beginning Loop Current Detection. (CA)

-1: Disable Loop Current Detection

Length: 2. Default: 400. Units: 10 ms

CA_LCDLY1

 Loop Current Delay 1: The delay after Loop Current Detection detects a transient drop in loop current and before Call Analysis returns a "connect" to the application. (CA)

Length: 2. Default: 10. Units: 10 ms

CA_HEDGE

Hello Edge: The point at which a "connect" will be returned to the application. (CA)

1. Rising Edge (immediately when a connect is detected)

2. Falling Edge (after the end of the salutation).

Length: 1. Default: 2. Units: edge

CA_CNOSIL

Continuous Nonsilence: The maximum length of the first or second period of nonsilence allowed. If exceeded, a "no ringback" is returned. (CA)

Length: 2. Default: 650. Units: 10 ms

CA_LO1TOLA

Low 1 Tolerance Above: Percent acceptable positive deviation of short low signal. (CA: Basic only)

Length: 1. Default: 13. Units: %

CA_LO1TOLB

Low 1 Tolerance Below: Percent acceptable negative deviation of short low signal. (CA: Basic only)

Length: 1. Default: 13. Units: %

CA_LO2TOLA

Low 2 Tolerance Above: Percent acceptable positive deviation of long low signal. (CA: Basic only)

Length: 1. Default: 13. Units: %.

CA_LO2TOLB

Low 2 Tolerance Below: Percent acceptable negative deviation of long low signal. (CA: Basic only)

Length: 1. Default: 13. Units: %

CA_HI1TOLA

High 1 Tolerance Above: Percent acceptable positive deviation of high signal. (CA: Basic only)

Length: 1. Default: 13. Units: %

CA_HI1TOLB

High 1 Tolerance Below: Percent acceptable negative deviation of high signal. (CA: Basic only)

Length: 1. Default: 13. Units: %

CA_LO1BMAX

Low 1 Busy Maximum: Maximum interval for short low for busy. (CA: Basic only)

Length: 2. Default: 90. Units: 10 ms.

CA_LO2BMAX

Low 2 Busy Maximum: Maximum interval for long low for busy. (CA: Basic only)

Length: 2. Default: 90. Units: 10 ms

CA_HI1BMAX

High 1 Busy Maximum: Maximum interval for first high for busy. (CA: Basic only)

Length: 2. Default: 90. Units: 10 ms

CA_NSBUSY

Nonsilence Busy: The number of nonsilence periods in addition to nbrdna to wait before returning a "busy." (CA: Basic only)

Length: 1. Default: 0. .Negative values are valid

CA_LOGLTCH

Low Glitch: The maximum silence period to ignore. Used to help eliminate spurious silence intervals. (CA)

Length: 2. Default: 15. Units: 10 ms

CA_HIGLTCH

High Glitch: The maximum nonsilence period to ignore. Used to help eliminate spurious nonsilence intervals. (CA)

Length: 2. Default: 19. Units: 10 ms

CA_LO1RMAX

Low 1 Ring Maximum: Maximum short low duration of double ring. (CA: Basic only)

Length: 2. Default: 90. Units: 10 ms

CA_LO2RMIN

Low 2 Ring Minimum: Minimum long low duration of double ring. (CA: Basic only)

Length: 2. Default: 225. Units: 10 ms

CA_INTFLG

Intercept Mode Flag: This parameter enables or disables SIT Frequency Detection, Positive Voice Detection (PVD), and/or Positive Answering Machine Detection (PAMD), and selects the mode of operation for Frequency Detection. (CA)

CA_INTFLTR

Not used.

CA_HISIZ

High Size: Used to determine whether to use alowmax or blowmax. (CA: Basic only)

Length: 2. Default: 90. Units: 10 ms

CA_ALOWMAX

A Low Maximum: Maximum low before connect if high > hisiz. (CA: Basic only)

Length: 2. Default: 700. Units: 10 ms

CA_BLOWMAX

B Low Maximum: Maximum low before connect if high < hisiz. (CA: Basic only)

Length: 2. Default: 530. Units: 10 ms

CA_NBRBEG

Number Before Beginning: Number of nonsilence periods before analysis begins. (CA: Basic only)

Length: 1. Default: 1. Units: rings

CA_HI1CEIL

High 1 Ceiling: Maximum 2nd high duration for a retrain. (CA: Basic only)

Length: 2. Default: 78. Units: 10 ms

CA_LO1CEIL

Low 1 Ceiling: Maximum 1st low duration for a retrain. (CA: Basic only)

Length: 2. Default: 58. Units: 10 ms

CA_LOWERFRQ

Lower Frequency: Lower bound for 1st tone in an SIT. (CA)

Length: 2. Default: 900. Units: Hz

CA_UPPERFRQ

Upper Frequency: Upper bound for 1st tone in an SIT. (CA)

Length: 2. Default: 1000. Units: Hz

CA_TIMEFRQ

Time Frequency: Minimum time for 1st tone in an SIT to remain in bounds. The minimum amount of time required for the audio signal to remain within the frequency detection range specified by upperfrq and lowerfrq for it to be considered valid. (CA)

Length: 1. Default: 5. Units: 10 ms

CA_REJCTFRQ

Not used

CA_MAXANSR

Maximum Answer: The maximum allowable length of ansrsize. When ansrsize exceeds maxansr, a "connect" is returned to the application. (CA)

Length: 2. Default: 1000. Units: 10 ms

CA_ANSRDGL

Answer Deglitcher: The maximum silence period allowed between words in a salutation. This parameter should be enabled only when you are interested in measuring the length of the salutation. (CA)

-1: Disable this condition

Length: 2. Default: -1. Units: 10 ms

CA_PVDMXPER

Not used.

CA_PVDSZWND

Not used.

CA_PVDDLY

Not used.

CA_MXTIMEFRQ

Maximum Time Frequency: Maximum allowable time for 1st tone in an SIT to be present.

Default: 0. Units: 10 ms

CA_LOWER2FRQ

Lower Bound for 2nd Frequency: Lower bound for 2nd tone in an SIT.

Default: 0. Units: Hz.

CA_UPPER2FRQ

 

Upper Bound for 2nd Frequency: Upper bound for 2nd tone in an SIT.

Default: 0. Units: Hz.

CA_TIME2FRQ

Time for 2nd Frequency: Minimum time for 2nd tone in an SIT to remain in bounds.

Default: 0. Units: 10 ms

CA_MXTIME2FRQ

Maximum Time for 2nd Frequency: Maximum allowable time for 2nd tone in an SIT to be present.

Default: 0. Units: 10 ms

CA_LOWER3FRQ

Lower Bound for 3rd Frequency: Lower bound for 3rd tone in an SIT.

Default: 0. Units: Hz

CA_UPPER3FRQ

Upper Bound for 3rd Frequency: Upper bound for 3rd tone in an SIT.

Default: 0. Units: Hz

CA_TIME3FRQ

Time for 3rd Frequency: Minimum time for 3rd tone in an SIT to remain in bounds.

Default: 0. Units: 10 ms

CA_MXTIME3FRQ

Maximum Time for 3rd Frequency: Maximum allowable time for 3rd tone in an SIT to be present.

Default: 0. Units: 10 ms.

CA_DTN_PRES

Dial Tone Present: Length of time that a dial tone must be continuously present. (CA: Enhanced only)

Default: 100. Units: 10 ms

CA_DTN_NPRES

Dial Tone Not Present: Maximum length of time to wait before declaring dial tone failure. (CA: Enhanced only)

Default: 300. Units: 10 ms

CA_DTN_DEBOFF

Dial Tone Debounce: Maximum gap allowed in an otherwise continuous dial tone before it is considered invalid. (CA: Enhanced only)

Default: 10. Units: 10 ms

CA_PAMD_FAILTIME

PAMD Fail Time: Maximum time to wait for Positive Answering Machine Detection or Positive Voice Detection after a cadence break. (CA: Enhanced only)

Default: 400. Units: 10 ms

CA_PAMD_MINRING

 Minimum PAMD Ring: Minimum allowable ring duration for Positive Answering Machine Detection. (CA: Enhanced only)

Default: 190. Units: 10 ms

CA_PAMD_SPDVAL

PAMD Speed Value: Quick or full evaluation for PAMD detection.

PAMD_FULL = Full evaluation of response

PAMD_QUICK = Quick look at connect circumstances (CA: Enhanced only)

PAMD_ACCU = Recommended setting. Does the most accurate evaluation detecting live voice as acurately as PAMD_FULL but is more accurate than PAMD_FULL (although slightly slower) in detecting an answering machine. Use PAMD_ACCU when accuracy is more important than speed.-

Default: PAMD_FULL

CA_PAMD_QTEMP

PAMD Qualification Template: Which PAMD template to use. Options are PAMD_QUAL1TMP or PAMD_QUAL2TMP; at present, only PAMD_QUAL1TMP is available. (CA: Enhanced only)

.

Default: PAMD_QUAL1TMP

CA_NOANSWER

No Answer: Length of time to wait after first ringback before deciding that the call is not answered. (CA: Enhanced only)

Default: 3000. Units: 10 ms

CA_MAXINTERING

Maximum Inter-ring Delay: Maximum time to wait between consecutive ringback signals before deciding that the call has been connected. (CA: Enhanced only)

Default: 800. Units: 10 ms.

DX_OPTDIS

Disable Frequency Detection and PVD

DX_OPTEN

Length: 1. Default

DX_OPTNOCON

Enable Frequency Detection return an "intercept" immediately after detecting a valid frequency

DX_PVDENABLE

Enable PVD

DX_PVDOPTEN

Enable PVD and DX_OPTEN

DX_PVDOPTNOCON

Enable PVD and DX_OPTNOCON

DX_PAMDENABLE

Enable PAMD

DX_PAMDOPTEN

Enable PAMD and DX_OPTEN