This document provides tables of operating systems and other programs that are compatible with ICONICS products. Requirements for unreleased products are subject to change before release.
Items labeled “Not Tested” are combinations that ICONICS does not explicitly test for or support, but for which there are no known issues. Items labeled “Not Supported” have known issues. ICONICS does not guarantee compatibility for either of these categories. Issues found in a “Not Tested” or “Not Supported” scenario may not be solvable by ICONICS Technical Support without migrating to a supported scenario.
Items labeled “Not Released” are the expected requirements/compatibilities and are subject to change before the final release.
This document is updated on a regular basis. For the most up-to-date copy, visit the Customer Connection Portal at https://getconnected.iconics.com.
Supported Operating Systems (Workstation Class) for GENESIS64
Supported Operating Systems (Server Class) for Hyper Historian
Supported Operating Systems (Workstation Class) for Hyper Historian
Supported Operating Systems (Workstation Class) for AnalytiX
Supported Operating Systems (Server Class) for MobileHMI Server
Supported Operating Systems (Workstation Class) for MobileHMI Server
Supported Operating Systems (Workstation Class) for GENESIS32
Supported Operating Systems (Server Class) for Embedded GENESIS32
Supported Operating Systems (Workstation Class) for Embedded GENESIS
Supported Web Browsers for BizViz (PortalWorX and Web Interfaces)
Supported Active Directory Services Versions for Integrated Security
Supported Versions of Excel for ReportWorX64, ReportWorX, and ReportWorX Express
|
Windows Server 2019 |
Windows Server 2016 |
Windows Server 2012 R2 |
Windows Server 2012 |
Windows Server 2008 R2 |
Windows Server 2008 x64 |
Windows Server 2003 x64 |
Other Server Class Operating Systems |
GENESIS64 10.97 (Released March 2021) |
Supported. |
Supported. |
Supported. |
Supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
GENESIS64 10.96.2 (Released November 2020) |
Supported. |
Supported. |
Supported. |
Supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
GENESIS64 10.96 & 10.96.1 (Released December 2019 & June 2020) |
Supported. |
Supported. |
Supported. |
Supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
GENESIS64 10.95 (Released June 2017) |
Supported with 10.95 Update 5 only. |
Supported. |
Supported. |
Supported. |
Service Pack 1. 3 |
Not supported. |
Not supported. |
Not supported. |
GENESIS64 10.9 (Released October 2015) |
Not tested. |
Not tested. |
Supported. |
Supported. |
Service Pack 1. 3 |
Supported. 3 |
Not supported. |
Not supported. |
GENESIS64 10.85 (Released August 2014) |
Not supported. |
Not supported. |
Supported. |
Supported. |
Service Pack 1. 3 |
Supported. 3 |
Not supported. |
Not supported. |
GENESIS64 10.81 (Released October 2013) |
Not supported. |
Not supported. |
Supported with ICONICS Hot Fix Pack 2 or later. |
Supported. |
Supported. 3 |
Supported. 3 |
Not supported. |
Not supported. |
GENESIS64 10.71 (Released October 2012) |
Not supported. |
Not supported. |
Not supported. |
Supported. |
Supported. |
Supported. |
Supported. |
Not supported. |
GENESIS64 10.61 (Released December 2011) |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Supported. |
Supported. |
Supported. |
Not supported. |
GENESIS64 10.51 (Released December 2010) |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Supported. |
Supported. |
Supported. |
Not supported. |
1 General Note: Web clients can also be 32-bit versions of these operating systems. Other than that, the supported operating systems for web clients are the same as for the servers.
2 Note for Embedded operating systems: ICONICS cannot guarantee compatibility with “Embedded” class operating systems. “Embedded” operating systems are often customized for their particular device, and if any operating system components were removed that our product relies on then those features will not function properly.
3 Note: AnyGlass Server for WebHMI (HTML5) in version 10.8x or later requires WebSockets not available in operating systems earlier than Windows 8 and Windows Server 2012.
|
Windows 10 x64 |
Windows 8.1 x64 |
Windows 8 x64 |
Windows 7 x64
|
Windows Vista 3 x64 |
Other Workstation Operating Systems |
GENESIS64 10.97 (Released March 2021) |
Professional, Enterprise, Enterprise 2016 LTSB, or Enterprise 2019 LTSC |
Professional or Enterprise. |
Not supported. |
Not tested. |
Not supported. |
Not supported. |
GENESIS64 10.96.2 (Released November 2020) |
Professional, Enterprise, Enterprise 2016 LTSB, or Enterprise 2019 LTSC |
Professional or Enterprise. |
Not supported. |
Service Pack 1, Professional or Enterprise. |
Not supported. |
Not supported. |
GENESIS64 10.96 & 10.96.1 (Released December 2019 & June 2020) |
Professional or Enterprise. |
Professional or Enterprise. |
Not supported. |
Service Pack 1, Professional or Enterprise. |
Not supported. |
Not supported. |
GENESIS64 10.95 (Released June 2017) |
Professional or Enterprise. |
Professional or Enterprise. |
Professional or Enterprise. |
Service Pack 1, Professional or Ultimate. |
Not supported. |
Not supported. |
GENESIS64 10.9 (Released October 2015) |
Professional or Enterprise. |
Professional or Enterprise. |
Professional or Enterprise. |
Service Pack 1, Professional or Ultimate. |
Service Pack 2. 4 |
Not supported. |
GENESIS64 10.85 (Released August 2014) |
Not supported. |
Professional or Enterprise. |
Professional or Enterprise. |
Service Pack 1, Professional or Ultimate. |
Service Pack 2. 4 |
Not supported. |
GENESIS64 10.81 (Released October 2013) |
Not supported. |
Professional or Enterprise, ICONICS Hot Fix Pack 2 or later. |
Professional or Enterprise. |
Professional or Ultimate. |
Service Pack 2. 3 |
Not supported. |
GENESIS64 10.71 (Released October 2012) |
Not supported. |
Not supported. |
Professional or Enterprise. |
Professional or Ultimate. |
Service Pack 2. |
Not supported. |
GENESIS64 10.61 (Released December 2011) |
Not supported. |
Not supported. |
Not supported. |
Professional or Ultimate. |
Service Pack 2. |
Not supported. |
GENESIS64 10.51 (Released December 2010) |
Not supported. |
Not supported. |
Not supported. |
Professional, Enterprise or Ultimate. |
Service Pack 2. |
Windows XP x64, Professional Edition. |
1 General Note: Web clients can also be 32-bit versions of these operating systems. Other than that, the supported operating systems for web clients are the same as for the servers.
2 Note for Embedded operating systems: ICONICS cannot guarantee compatibility with “Embedded” class operating systems. “Embedded” operating systems are often customized for their particular device, and if any operating system components were removed that our product relies on then those features will not function properly.
3 Note for Vista: Any supported products will run only on Business, Ultimate, and Enterprise editions.
4 Note: AnyGlass Server for WebHMI (HTML5) in version 10.8x or later requires WebSockets not available in operating systems earlier than Windows 8 and Windows Server 2012.
|
Windows Server 2019 |
Windows Server 2016 |
Windows Server 2012 R2 |
Windows Server 2012 |
Windows Server 2008 R2 |
Windows Server 2008 x64 |
Other Server Class Operating Systems |
Hyper Historian 10.97 (Released March 2021) |
Supported. |
Supported. |
Supported. |
Supported. |
Not supported. |
Not supported. |
Not supported. |
Hyper Historian 10.96.2 (Released November 2020) |
Supported. |
Supported. |
Supported. |
Supported. |
Not supported. |
Not supported. |
Not supported. |
Hyper Historian 10.96 & 10.96.1 (Released December 2019 & June 2020) |
Supported. |
Supported. |
Supported. |
Supported. |
Not supported. |
Not supported. |
Not supported. |
Hyper Historian 10.95 (Released June 2017) |
Supported with 10.95 Update 5 only. |
Supported. |
Supported. |
Supported. |
Service Pack 1. 3 |
Not supported. |
Not supported. |
Hyper Historian 10.9 (Released October 2015) |
Not tested. |
Not tested. |
Supported. |
Supported. |
Service Pack 1. 3 |
Supported. 3 |
Not supported. |
Hyper Historian 10.85 (Released August 2014) |
Not supported. |
Not supported. |
Supported. |
Supported. |
Service Pack 1. 3 |
Supported. 3 |
Not supported. |
Hyper Historian 10.81 (Released October 2013) |
Not supported. |
Not supported. |
Supported with ICONICS Hot Fix Pack 2 or later. |
Supported. |
Supported. 3 |
Supported. 3 |
Not supported. |
Hyper Historian 10.71 (Released October 2012) |
Not supported. |
Not supported. |
Not supported. |
Supported. |
Supported. |
Service Pack 2. |
Not supported. |
Hyper Historian 10.61 (Released December 2011) |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Supported. |
No Service Pack or Service Pack 2. |
Not supported. |
Hyper Historian 10.51 (Released December 2010) |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Supported. |
Supported. |
Not supported. |
1 General Note: Web clients can also be 32-bit versions of these operating systems. Other than that, the supported operating systems for web clients are the same as for the servers.
2 Note for Embedded operating systems: ICONICS cannot guarantee compatibility with “Embedded” class operating systems. “Embedded” operating systems are often customized for their particular device, and if any operating system components were removed that our product relies on then those features will not function properly.
3 Note: AnyGlass Server for WebHMI (HTML5) in version 10.8x or later requires WebSockets not available in operating systems earlier than Windows 8 and Windows Server 2012.
|
Windows 10 x64 |
Windows 8.1 x64 |
Windows 8 x64 |
Windows 7 x64 |
Windows Vista 3 x64 |
Other Workstation Operating Systems |
Hyper Historian 10.97 (Released March 2021) |
Professional, Enterprise, Enterprise 2016 LTSB, or Enterprise 2019 LTSC. |
Professional or Enterprise. |
Not supported. |
Not tested. |
Not supported. |
Not supported. |
Hyper Historian 10.96.2 (Released November 2020) |
Professional or Enterprise. |
Not supported. |
Service Pack 1, Professional or Enterprise. 3 |
Not supported. |
Not supported. |
|
Hyper Historian 10.96 & 10.96.1 (Released December 2019 & June 2020) |
Professional or Enterprise. |
Professional or Enterprise. |
Not supported. |
Not supported. |
Not supported. |
|
Hyper Historian 10.95 (Released June 2017) |
64-bit only. |
Professional or Enterprise. |
Professional or Enterprise. |
Not supported. |
Not supported. |
|
Hyper Historian 10.9 (Released October 2015) |
64-bit only. |
Professional or Enterprise. |
Professional or Enterprise. |
Service Pack 2. 3 |
Not supported. |
|
Hyper Historian 10.85 (Released August 2014) |
Not supported. |
Professional or Enterprise. |
Professional or Enterprise. |
Service Pack 2. 3 |
Not supported. |
|
Hyper Historian 10.81 (Released October 2013) |
Not supported. |
Professional or Enterprise, ICONICS Hot Fix Pack 2 or later. |
Professional or Enterprise. |
Professional or Enterprise. 3 |
Service Pack 2. 3 |
Not supported. |
Hyper Historian 10.71 (Released October 2012) |
Not supported. |
Not supported. |
Professional or Enterprise. |
Professional or Enterprise. |
Service Pack 2. |
Not supported. |
Hyper Historian 10.61 (Released December 2011) |
Not supported. |
Not supported. |
Not supported. |
Professional or Ultimate. |
Service Pack 2. |
Not supported. |
Hyper Historian 10.51 (Released December 2010) |
Not supported. |
Not supported. |
Not supported. |
Professional, Enterprise, and Ultimate. |
Service Pack 2. |
Windows XP x64, Professional Edition |
1 General Note: Web clients can also be 32-bit versions of these operating systems. Other than that, the supported operating systems for web clients are the same as for the servers.
2 Note for Embedded operating systems: ICONICS cannot guarantee compatibility with “Embedded” class operating systems. “Embedded” operating systems are often customized for their particular device, and if any operating system components were removed that our product relies on then those features will not function properly.
3Note for Vista: Any supported products will run only on Business, Ultimate, and Enterprise editions.
4 Note: AnyGlass Server for WebHMI (HTML5) in version 10.8x or later requires WebSockets not available in operating systems earlier than Windows 8 and Windows Server 2012.
|
Windows Server 2019 |
Windows Server 2016 |
Windows Server 2012 R2 |
Windows Server 2012 |
Windows Server 2008 R2 |
Windows Server 2008 x64 |
Other Operating Systems |
AnalytiX 10.97 (Released March 2021) . |
Supported. |
Supported. |
Supported. |
Supported. |
Not supported. |
Not supported. |
Not supported |
AnalytiX 10.96.2 (Released November 2020) |
Supported. |
Supported. |
Supported. |
Supported. |
Not supported. |
Not supported. |
Not supported. |
AnalytiX 10.96 & 10.96.1 (Released December 2019 & June 2020) |
Supported. |
Supported. |
Supported. |
Supported. |
Not supported. |
Not supported. |
Not supported. |
AnalytiX 10.95 (Released June 2017) |
Supported with 10.95 Update 5 only. |
Supported. |
Supported. |
Supported. |
Service Pack 1. 3 |
Not supported. |
Not supported. |
AnalytiX 10.9 (Released October 2015) |
Not tested. |
Not tested. |
Supported. |
Supported. |
Service Pack 1. 3 |
Supported. 3 |
Not supported. |
AnalytiX 10.85 (Released August 2014) |
Not supported. |
Not supported. |
Supported. |
Supported. |
Service Pack 1. 3 |
Supported. 3 |
Not supported. |
AnalytiX 10.81 (Released October 2013) |
Not supported. |
Not supported. |
Supported with ICONICS Hot Fix Pack 2 or later. |
Supported. |
Supported. 3 |
Supported. 3 |
Not supported. |
AnalytiX 10.71 (Released October 2012) |
Not supported. |
Not supported. |
Not supported. |
Supported. |
Supported. |
Supported. |
Not supported. |
AnalytiX 10.61 (Released December 2011) |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Service Pack 2. |
Supported. |
Not supported. |
1 General Note: Web clients can also be 32-bit versions of these operating systems. Other than that, the supported operating systems for web clients are the same as for the servers.
2 Note for Embedded operating systems: ICONICS cannot guarantee compatibility with “Embedded” class operating systems. “Embedded” operating systems are often customized for their particular device, and if any operating system components were removed that our product relies on then those features will not function properly.
3 Note: AnyGlass Server for WebHMI (HTML5) in version 10.8x or later requires WebSockets not available in operating systems earlier than Windows 8 and Windows Server 2012.
|
Windows 10 x64 |
Windows 8.1 x64 |
Windows 8 x64 |
Windows 7 3 x64 |
Windows Vista 4 x64 |
Other Operating Systems |
AnalytiX 10.97 (Released March 2021) |
Not Supported, except as web clients. |
Not Supported, except as web clients, then Professional or Enterprise only. 5 |
Not Tested. |
Not supported. |
Not supported. |
|
AnalytiX 10.96.2 (Released November 2020) |
Not Supported, except as web clients, then Professional or Enterprise only. 5 |
Not supported. |
Not supported. |
|||
AnalytiX 10.96 & 10.96.1 (Released December 2019 & June 2020) |
Not supported. |
Not supported. |
||||
AnalytiX 10.95 (Released June 2017) |
Not supported. |
Not supported. |
||||
AnalytiX 10.9 (Released October 2015) |
Not Supported, except as web clients, then Service Pack 2 only. 5 |
Not supported. |
||||
AnalytiX 10.85 (Released August 2014) |
Not supported. |
Not Supported, except as web clients. |
Not Supported, except as web clients, then Service Pack 2 only. 5 |
Not supported. |
||
AnalytiX 10.81 (Released October 2013) |
Not supported. |
Professional or Enterprise, ICONICS Hot Fix Pack 2 or later. |
Professional or Enterprise. |
Professional or Enterprise. 5 |
Supported. 5 |
Not supported. |
AnalytiX 10.71 (Released October 2012) |
Not supported. |
Not supported. |
Professional or Enterprise. |
Professional or Enterprise. |
Supported. |
Not supported. |
AnalytiX 10.61 (Released December 2011) |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
1 General Note: Web clients can also be 32-bit versions of these operating systems. Other than that, the supported operating systems for web clients are the same as for the servers.
2 Note for Embedded operating systems: ICONICS cannot guarantee compatibility with “Embedded” class operating systems. “Embedded” operating systems are often customized for their particular device, and if any operating system components were removed that our product relies on then those features will not function properly.
3 Note for Windows 7: Any supported products will run only on Professional, Enterprise, and Ultimate editions.
4 Note for Vista: Any supported products will run only on Business, Ultimate, and Enterprise editions.
5 Note: AnyGlass Server for WebHMI (HTML5) in version 10.8x or later requires WebSockets not available in operating systems earlier than Windows 8 and Windows Server 2012.
|
Windows Server 2019 |
Windows Server 2016 |
Windows Server 2012 R2 |
Windows Server 2012 |
Windows Server 2008 R2 |
Windows Server 2008 x64 |
Windows Server 2003 x64 |
Other Server Operating Systems |
MobileHMI 10.97 2 (Released March 2021) |
Supported. |
Supported. |
Supported. |
Supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported |
MobileHMI 10.96.2 2 (Released November 2020) |
Supported. |
Supported. |
Supported. |
Supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported |
MobileHMI 10.96 & 10.96.1 2 (Released December 2019 & June 2020) |
Supported. |
Supported. |
Supported. |
Supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
MobileHMI 10.95 2 (Released June 2017) |
Supported with 10.95 Update 5 only. |
Supported. |
Supported. |
Supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
MobileHMI 10.9 2 (Released October 2015) |
Not supported. |
Not supported. |
Supported. |
Supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
MobileHMI 10.85 2 (Released August 2014) |
Not supported. |
Not supported. |
Supported. |
Supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
MobileHMI 10.81 2 (Released October 2013) |
Not supported. |
Not supported. |
Supported with ICONICS Hot Fix Pack 2 or later. |
Supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
MobileHMI 10.71 (Released October 2012) |
Not supported. |
Not supported. |
Not supported. |
Supported. |
Supported. |
Supported. |
Supported. |
Not supported. |
MobileHMI 10.61 (Released December 2011) |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Supported. |
Supported. |
Supported. |
Not supported. |
1 Note for Embedded operating systems: ICONICS cannot guarantee compatibility with “Embedded” class operating systems. “Embedded” operating systems are often customized for their particular device, and if any operating system components were removed that our product relies on then those features will not function properly.
2 Note: AnyGlass Server for MobileHMI and WebHMI (HTML5) in version 10.8x or later requires WebSockets not available in operating systems earlier than Windows 8 and Windows Server 2012.
|
Windows 10 x64 |
Windows 8.1 x64 |
Windows 8 x64 |
Windows 7 x64 |
Windows Vista x64 |
Other Workstation Operating Systems |
MobileHMI 10.97 2 (Released March 2021) |
Not Supported, except as web clients. |
Not Supported, except as web clients. |
Not Supported, except as web clients, then Professional or Enterprise only. |
Not tested. |
Not Supported, except as web clients, then Service Pack 2 only. |
Not supported. |
MobileHMI 10.96 & 10.96.2 2 (Released November 2020) |
Not Supported, except as web clients. |
Not Supported, except as web clients. |
Not Supported, except as web clients, then Professional or Enterprise only. |
Not supported. |
||
MobileHMI 10.96 & 10.96.1 2 (Released December 2019 & June 2020) |
Not Supported, except as web clients. |
Not Supported, except as web clients. |
Not supported. |
|||
MobileHMI 10.95 2 (Released June 2017) |
Not Supported, except as web clients. |
Not Supported, except as web clients. |
Not supported. |
|||
MobileHMI 10.9 2 (Released October 2015) |
Not Supported, except as web clients. |
Not Supported, except as web clients. |
Not supported. |
|||
MobileHMI 10.85 2 (Released August 2014) |
Not supported. |
Not Supported, except as web clients. |
Not supported. |
|||
MobileHMI 10.81 2 (Released October 2013) |
Not supported. |
Professional or Enterprise, ICONICS Hot Fix Pack 2 or later. |
Professional or Enterprise. |
Not Supported, except as web clients, then Professional or Enterprise only. |
Not supported. |
|
MobileHMI 10.71 (Released October 2012) |
Not supported. |
Not supported. |
Professional or Enterprise. |
Professional or Ultimate. |
Service Pack 2. |
Not supported. |
MobileHMI 10.61 (Released December 2011) |
Not supported. |
Not supported. |
Not supported. |
Professional or Ultimate. |
Service Pack 2. |
Not supported. |
1 Note for Embedded operating systems: ICONICS cannot guarantee compatibility with “Embedded” class operating systems. “Embedded” operating systems are often customized for their particular device, and if any operating system components were removed that our product relies on then those features will not function properly.
2 Note: AnyGlass Server for MobileHMI and WebHMI (HTML5) in version 10.8x or later requires WebSockets not available in operating systems earlier than Windows 8 and Windows Server 2012.
|
Windows Server 2019 |
Windows Server 2016 |
Windows Server 2012 R2 |
Windows Server 2012 |
Windows Server 2008 R2 |
Windows Server 2008 |
Windows Server 2003 |
Older Operating Systems |
GENESIS32 9.6 (Released March 2020) |
Supported. |
Supported. |
Supported. |
Supported. |
Supported. |
Not tested. |
Not tested. |
Not supported. |
GENESIS32 9.5 (Released July 2017) |
Not tested. |
Supported. |
Supported. |
Supported. |
Supported. |
Service Pack 2. |
Not tested. |
Not supported. |
GENESIS32 9.4 (Released November 2015) |
Not tested. |
Not tested. |
Supported. |
Supported. |
Supported. |
Service Pack 2. |
32-bit only. Service Pack 2. |
Not supported. |
GENESIS32 9.35 (Released August 2014) |
Not supported. |
Not supported. |
Supported. |
Supported. |
Supported. |
Service Pack 2. |
32-bit only. Service Pack 2. |
Not supported. |
GENESIS32 9.30 (Released October 2013) |
Not supported. |
Not supported. |
Not supported. |
Supported. |
Supported. |
Service Pack 2. |
32-bit only. Service Pack 2. |
Not supported. |
GENESIS32 9.22 (Released July 2011) |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Supported. |
Service Pack 2. |
32-bit only. Service Pack 2. |
Not supported. |
GENESIS32 9.13 (Released September 2008) |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Supported. |
32- and 64-bit. 1 No Service Pack, Service Pack 2, or R2. |
Windows 2000 SP4, Server or Workstation. |
GENESIS32 9.01 (Released January 2007) |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
32- and 64-bit. 1 No Service Pack, Service Pack 1, or R2. |
Windows 2000 SP4, Server or Workstation. |
GENESIS32 8.05 (Released November 2008) |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
32-bit only. |
Windows NT, Windows 2000 Server or Workstation. |
GENESIS32 7.2 (Released January 2005) |
Windows 98 SE (non-Unicode), ME, or NT 4.0 SP6a. Windows 2000 SP3, Server or Workstation. |
1 Note for all 64-bit operating systems: All supported 32-bit products will run in 32-bit compatibility mode on 64-bit operating systems.
2 Note for Embedded operating systems: ICONICS cannot guarantee compatibility with “Embedded” class operating systems. “Embedded” operating systems are often customized for their particular device, and if any operating system components were removed that our product relies on then those features will not function properly. There is an application note entitled, “Embedded GENESIS32 – Configuring Embedded Operating Systems” that can help you ensure compatibility.
|
Windows 10 3 |
Windows 8.1 4 |
Windows 8 4 |
Windows 7 4 |
Windows Vista 5 |
Windows XP 6 |
Older Operating Systems |
GENESIS32 9.6 (Released March 2020) |
Supported. |
Supported. |
Supported. |
Supported. |
Not tested. |
Not tested. |
Not supported. |
GENESIS32 9.5 (Released July 2017) |
Supported. |
Supported. |
Supported. |
Supported. |
Service Pack 2. |
Not tested. |
Not supported. |
GENESIS32 9.4 (Released Nov. 2015) |
Supported. |
Supported. |
Supported. |
Supported. |
Service Pack 2. |
32-bit only. Service Pack 3. |
Not supported. |
GENESIS32 9.35 (Released August 2014) |
Not supported. |
Supported. |
Supported. |
Supported. |
Service Pack 2. |
32-bit only. Service Pack 3. |
Not supported. |
GENESIS32 9.30 (Released October 2013) |
Not supported. |
Not supported. |
Supported. |
Supported. |
Service Pack 2. |
32-bit only. Service Pack 3. |
Not supported. |
GENESIS32 9.22 (Released July 2011) |
Not supported. |
Not supported. |
Not supported. |
Supported. |
Service Pack 2. |
32-bit only. Service Pack 3. |
Not supported. |
GENESIS32 9.13 (Released Sept. 2008) |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Supported. |
32- and 64-bit. 1 Service Pack 2 or 3. |
Windows 2000 SP4, Server or Workstation. |
GENESIS32 9.01 (Released January 2007) |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
No Service Pack. Must run in 32x32 mode with UAC disabled. |
32- and 64-bit. 1 Service Pack 1 or 2. |
Windows 2000 SP4, Server or Workstation. |
GENESIS32 8.05 (Released Nov. 2008) |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
32-bit only. Service Pack 2. |
Windows NT, Windows 2000 Server or Workstation. |
GENESIS32 7.2 (January 2005) |
Windows XP, SP1, Windows 98 SE (non-Unicode), ME, or NT 4.0 SP6a. Windows 2000 SP3, Server or Workstation. |
1 Note for all 64-bit operating systems: All supported 32-bit products will run in 32-bit compatibility mode on 64-bit operating systems.
2 Note for Embedded operating systems: ICONICS cannot guarantee compatibility with “Embedded” class operating systems. “Embedded” operating systems are often customized for their particular device, and if any operating system components were removed that our product relies on then those features will not function properly. There is an application note entitled, “Embedded GENESIS32 – Configuring Embedded Operating Systems” that can help you ensure compatibility.
3 Note for Windows 10: Any supported products will run only on Professional or Enterprise. Home, Mobile, Mobile Enterprise, Education, IoT Core are not currently supported.
4 Note for Windows 7 and Windows 8: Any supported products will run only on Professional, Enterprise, and Ultimate editions.
5 Note for Vista: Any supported products will run only on Business, Ultimate, and Enterprise editions.
6Notes for XP: Any supported products will run only on Professional Edition. “64-bit” in the Window XP column refers to “Windows XP x64 Edition”, not “Windows XP 64-bit Edition”.
|
Windows Server 2019 |
Windows Server 2016 |
Windows Server 2012 R2 |
Windows Server 2012 |
Windows Server 2008 R2 |
Windows Server 2008 |
Windows Server 2003 |
Older Operating Systems |
BizViz 9.6 (Released March 2020) |
Supported. |
Supported. |
Supported. |
Supported. |
Supported. |
Not tested. |
Not tested. |
Not supported. |
BizViz 9.5 (Released July 2017) |
Not tested. |
Supported. |
Supported. |
Supported. |
Supported. |
Service Pack 2. |
Not tested. |
Not supported. |
BizViz 9.4 (Released November 2015) |
Not tested. |
Not tested. |
Supported. |
Supported. |
Supported. |
Service Pack 2. |
32-bit only. Service Pack 2. |
Not supported. |
BizViz 9.35 (Released August 2014) |
Not supported. |
Not supported. |
Supported. |
Supported. |
Supported. |
Service Pack 2. |
32-bit only. Service Pack 2. |
Not supported. |
BizViz 9.30 (Released October 2013) |
Not supported. |
Not supported. |
Not supported. |
Supported. |
Supported. |
Service Pack 2. |
32-bit only. Service Pack 2. |
Not supported. |
BizViz 9.22 (Released September 2011) |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Supported. |
Service Pack 2. |
32-bit only. Service Pack 2. |
Not supported. |
BizViz 9.13 (Released November 2008) |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
32- and 64-bit. 1
Unified Web Interface and PortalWorX may not be able to run alongside 64-bit web apps, including GENESIS64. |
32- and 64-bit. 1
No Service Pack, Service Pack 2, or R2. |
Not supported. |
BizViz 9.01 (Released March 2007) |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
32- and 64-bit. 1
No Service Pack, Service Pack 1, or R2. |
Windows 2000 SP4, Server or Workstation. |
BizViz 8.04 (Released December 2006) |
Windows Server 2003 (32-bit only), Windows 2000 Server or Workstation, Windows 98 (non-Unicode), Windows ME (non-Unicode), NT 4.0. |
1 Note for all 64-bit operating systems: All supported 32-bit products will run in 32-bit compatibility mode on 64-bit operating systems.
2 Note for Embedded operating systems: ICONICS cannot guarantee compatibility with “Embedded” class operating systems. “Embedded” operating systems are often customized for their particular device, and if any operating system components were removed that our product relies on then those features will not function properly.
|
Windows 10 4 |
Windows 8.1 5 |
Windows 8 5 |
Windows 7 5 |
Windows Vista 6 |
Windows XP 7 |
Older Operating Systems |
BizViz 9.6 (Released March 2020) |
Pro and Enterprise. |
Supported. |
Supported. |
Supported. |
Not tested. |
Not supported. |
Not supported. |
BizViz 9.5 (Released July 2017) |
Pro and Enterprise. |
Supported. |
Supported. |
Supported. |
Service Pack 2. |
Not supported. |
Not supported. |
BizViz 9.4 (Released Nov. 2015) |
Pro and Enterprise. |
Supported. |
Supported. |
Supported. |
Service Pack 2. |
32-bit only. Service Pack 3. |
Not supported. |
BizViz 9.35 (Released Aug. 2014) |
Not supported. |
Supported. |
Supported. |
Supported. |
Service Pack 2. |
32-bit only. Service Pack 3. |
Not supported. |
BizViz 9.30 (Released Oct. 2013) |
Not supported. |
Not supported. |
Supported. |
Supported. |
Service Pack 2. |
32-bit only. Service Pack 3. |
Not supported. |
BizViz 9.22 (Released Sept. 2011) |
Not supported. |
Not supported. |
Not supported. |
Supported. |
Service Pack 2. |
32-bit only. Service Pack 3. |
Not supported. |
BizViz 9.13 (Released November 2008) |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
32- and 64-bit. 2 Service Pack 1. |
32- and 64-bit. 2
Service Pack 2 or 3. |
Not supported. |
BizViz 9.01 (Released March 2007) |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
32-bit only.
Must turn off UAC in order to install. |
32- and 64-bit. 2
Service Pack 1 or 2. |
Windows 2000 SP4, Server or Workstation. |
BizViz 8.04 (Released Dec. 2006) |
Windows XP (32-bit), Windows 2000 Server or Workstation, Windows 98 (non-Unicode), Windows ME (non-Unicode), NT 4.0. |
1 General Note: SharePoint and PortalWorX are only supported on server-class operating systems.
2 Note for all 64-bit operating systems: All supported 32-bit products will run in 32-bit compatibility mode on 64-bit operating systems.
3 Note for Embedded operating systems: ICONICS cannot guarantee compatibility with “Embedded” class operating systems. “Embedded” operating systems are often customized for their particular device, and if any operating system components were removed that our product relies on then those features will not function properly.
4 Note for Windows 10: Home, Mobile, Mobile Enterprise, Education, IoT Core are not currently supported.
5 Note for Windows 7 and Windows 8: Any supported products will run only on Professional, Enterprise, and Ultimate editions.
6 Note for Vista: Any supported products will run only on Business, Ultimate, and Enterprise editions.
7 Note for XP: Any supported products will run only on Professional Edition. “64-bit” in the Window XP column refers to “Windows XP x64 Edition”, not “Windows XP 64-bit Edition”.
|
Windows Server 2019 |
Windows Server 2016 |
Windows Server 2012 R2 |
Windows Server 2012 |
Windows Server 2008 R2 |
Windows Server 2008 |
Windows Server 2003 |
Windows 2000 |
Windows NT 4.0 |
Embedded GENESIS32 9.6 (Released March 2020) |
Supported. |
Supported. |
Supported. |
Supported. |
Supported. |
Not tested. |
Not tested. |
Not supported. |
Not supported. |
Embedded GENESIS32 9.5 (Released July 2017) |
Not tested. |
Supported. |
Supported. |
Supported. |
Supported. |
Service Pack 2. |
32-bit, Service Pack 2. |
Not supported. |
Not supported. |
Embedded GENESIS32 9.4 (Released November 2015) |
Not supported. |
Not supported. |
Supported. |
Supported. |
Supported. |
Service Pack 2. |
32-bit. |
Not supported. |
Not supported. |
Embedded GENESIS32 9.35 (Released October 2014) |
Not supported. |
Not supported. |
Supported. |
Supported. |
Supported. |
Service Pack 2. |
32-bit. |
Not supported. |
Not supported. |
Embedded GENESIS32 9.01 (Released May 2007) |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
32-bit. |
Server or Workstation. |
Standard and Embedded versions.
Service Pack 6a. |
Embedded GENESIS32 7.01 (Released May 2003) |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Server or Workstation. |
Standard and Embedded versions.
Service Pack 6a. |
1 Note for all 64-bit operating systems: All supported 32-bit products will run in 32-bit compatibility mode on 64-bit operating systems.
2 Note for Embedded operating systems: ICONICS cannot guarantee compatibility with “Embedded” class operating systems. “Embedded” operating systems are often customized for their particular device, and if any operating system components were removed that our product relies on then those features will not function properly. There is an application note entitled, “Embedded GENESIS32 – Configuring Embedded Operating Systems” that can help you ensure compatibility.
|
Windows 10 3 |
Windows 8.1 3 5 |
Windows 8 3 5 |
Windows 7 4 5 |
Windows Vista 6 |
Windows XP 7 |
Windows 2000 |
Embedded GENESIS 9.6 (Released March 2020) |
Supported. |
Supported. |
Supported. |
Supported. |
Not tested. |
Not tested. |
Not supported. |
Embedded GENESIS 9.5 (Released July 2017) |
Supported. |
Supported. |
Supported. |
Supported. |
Service Pack 2. |
32-bit. Standard and Embedded versions. |
Not supported. |
Embedded GENESIS 9.4 (Released November 2015) |
Supported. |
Supported. |
Supported. |
Supported. |
Service Pack 2. |
32-bit. Standard and Embedded versions. |
Not supported. |
Embedded GENESIS 9.35 (Released October 2014) |
Not supported. |
Supported. |
Supported. |
Supported. |
Service Pack 2. |
32-bit. Standard and Embedded versions. |
Not supported. |
Embedded GENESIS 9.01 (Released May 2007) |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Supported. |
Standard and Embedded versions. |
Server or Workstation. |
Embedded GENESIS 7.01 (Released May 2003) |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Standard and Embedded versions. |
Server or Workstation. |
1 Note for all 64-bit operating systems: All supported 32-bit products will run in 32-bit compatibility mode on 64-bit operating systems.
2 Note for Embedded or IoT Core operating systems: ICONICS cannot guarantee compatibility with “Embedded” class operating systems. “Embedded” operating systems are often customized for their particular device, and if any operating system components were removed that our product relies on then those features will not function properly. There is an application note entitled, “Embedded GENESIS32 – Configuring Embedded Operating Systems” that can help you ensure compatibility.
3Note for Windows 8, 8.1, and 10: Any supported products will only run on Pro and Enterprise editions.
4Note for Windows 7: Any supported products will only run on Professional, Ultimate, and Enterprise editions.
5Note for Windows 7 and 8: See the application note entitled “Embedded GENESIS32 – Configuring Embedded Operating Systems for more detail on how to properly install these embedded operating systems to be compatible with Embedded GENESIS.
6Note for Vista: Any supported products will run only on Business, Ultimate, and Enterprise editions.
7Note for XP: Any supported products will run only on Professional edition.
|
IoTWorX 10.96, 10.96.1, 10.96.2, 10.97 (Released December 2019 - March 2021) |
IoTWorX 10.95 (Released June 2017) |
Windows IoT Enterprise |
Not Supported – use 10.95 Update 5 2 |
Supported |
Raspbian 3 |
Raspbian Stretch (ARM32v7) |
Not Supported |
Ubuntu |
Ubuntu 16.04 (AMD64) Ubuntu 18.04 (AMD64) |
Not Supported |
Ubuntu Server |
Ubuntu Server 16.04 (AMD64) Ubuntu Server 18.04 (AMD64) |
Not Supported |
Other Linux (Azure IoT Edge Tier 2 Support) |
Customers may choose other Linux AMD64 or ARM32v7 operating systems from the list of Tier 2 Azure IoT Edge supported operating systems. Compatibility can be reasonably assumed for Tier 2 Linux AMD64 or ARM32v7 operating systems but is not guaranteed.
|
Not Supported |
1 General Note: These listed operating systems are only for the software installed on the edge device. The IoTWorX configuration software can be installed on any operating system supported by GENESIS64 or ICONICS Suite.
2 10.96 & 10.96.1 Windows IoT Enterprise Note: Version 10.96 and 10.96.1 of ICONICS Suite, GENESIS64, or server-side IoTWorX can support a Windows IoT Enterprise edge device when using IoTWorX 10.95 Update 5 edge software.
3 Raspbian Buster is currently not supported due to recent changes in the operating system that prevent the Microsoft IoT Edge software from functioning. Support will be restored once third-party software issues are resolved.
|
Windows 7, Windows Server 2008 R2, or Newer |
Windows Server 2008 |
Windows Vista 2 |
Windows Server 2003 |
Windows XP 3 |
Windows 2000 |
Older Operating Systems |
OPC ToolWorX 3.5 (Released April 2009) |
Not tested. |
32-bit and 64-bit. |
Service Pack 1.
32-bit and 64-bit. |
Service Pack 2.
32-bit and 64-bit. |
Service Pack 3. |
Service Pack 4. |
Not supported. |
OPC ToolWorX 3.2 (Released September 2006) |
Not supported. |
Not supported. |
Not supported. |
32-bit only. |
Supported. |
Supported. |
Windows NT 4.0 with DCOM installed. |
OPC ToolWorX 3.12 (Released March 2005) |
Not supported. |
Not supported. |
Not supported. |
32-bit only. |
Supported. |
Supported. |
Windows NT 4.0 with DCOM installed. |
1 Note for Embedded operating systems: ICONICS cannot guarantee compatibility with “Embedded” class operating systems. “Embedded” operating systems are often customized for their particular device, and if any operating system components were removed that our product relies on then those features will not function properly.
2 Note for Vista: Any supported products will run only on Business, Ultimate, and Enterprise editions (not Home or Home Premium).
3 Note for XP: Any supported products will run only on Professional Edition (not Home).
|
Microsoft Visual Studio 2010 & 2012 |
Microsoft Visual Studio 2008 |
Microsoft Visual Studio 2005 |
Microsoft Visual Studio Express (2005 or 2008) |
Microsoft Visual Studio .NET 2003 |
Microsoft Visual C++ Version 6.0 |
OPC ToolWorX 3.5 (Released April 2009) |
Not supported. |
Supported. |
Supported. |
Not supported. |
Supported. |
Supported. |
OPC ToolWorX 3.2 (Released September 2006) |
Not supported. |
Not supported. |
Supported. |
Not supported. |
Supported. |
Supported. |
OPC ToolWorX 3.12 (Released March 2005) |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Supported. |
Supported. |
|
SQL Azure |
SQL Server 2019 |
SQL Server 2017 |
SQL Server 2016 |
SQL Server 2014 |
SQL Server 2012 |
SQL Server 2008 R2 |
SQL Server 2008 |
SQL Server 2005 |
GENESIS64 10.97 (Released March 2021) |
Supported except FDDWorX and AlarmWorX64 Multimedia. |
Supported. |
Supported. |
Supported. |
Supported. |
Not tested. |
Not supported. |
Not supported. |
Not supported |
GENESIS64 10.96.2 (Released November 2020 |
Supported except Project Reporting, FDDWorX, and AlarmWorX64 Multimedia. |
Supported. |
Supported. |
Supported. |
Supported. |
Supported. |
Not supported. |
Not supported. |
Not supported. |
GENESIS64 10.96 & 10.96.1 (Released December 2019 & June 2020) |
Supported. |
Supported. |
Supported. |
Supported. |
Supported. |
Not supported. |
Not supported. |
Not supported. |
|
GENESIS64 10.95 (Released June 2017) |
Not tested. |
Supported with ICONICS Update 4 or later. |
Supported. |
Supported. |
Supported. |
Service Pack 1. |
Not supported. |
Not supported. |
|
GENESIS64 10.9 (Released October 2015) |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Supported. |
Supported. |
Service Pack 1. |
Not supported. |
Not supported. |
GENESIS64 10.85 (Released August 2014) |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Supported. |
Supported. |
Service Pack 1. |
Not supported. |
Not supported. |
GENESIS64 10.81 (Released October 2013) |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Supported. |
Service Pack 1. |
Service Pack 2. |
Service Pack 4. |
GENESIS64 10.71 (Released October 2012) |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Supported. |
Service Pack 1. |
Service Pack 2. |
Service Pack 4. |
GENESIS64 10.61 (Released December 2011) |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Supported. |
Supported. |
Service Pack 2. |
GENESIS64 10.51 (Released December 2010) |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Not tested. |
Supported. |
Service Pack 2. |
1 Notes: The connection to SQL Server data source may be either local or remote. ICONICS supports SQL databases with encryption. Express editions also supported. Earlier versions of SQL Server or other databases are not supported for configuration or logging databases. However, they may be used as data sources in GridWorX Server.
|
SQL Azure |
SQL Server 2019 |
SQL Server 2017 |
SQL Server 2016 |
SQL Server 2014 |
SQL Server 2012 |
SQL Server 2008 R2 |
SQL Server 2008 |
SQL Server 2005 |
AnalytiX 10.97 (Released March 2021) |
Not supported. |
Supported. |
Supported. |
Supported. |
Supported. |
Not tested. |
Not supported. |
Not supported. |
Not supported. |
AnalytiX 10.96.2 (Released November 2020) |
Not supported. |
Supported. |
Supported. |
Supported. |
Supported.. |
Supported. |
Not supported. |
Not supported. |
Not supported. |
AnalytiX 10.96 & 10.96.1 (Released December 2019 & June 2020) |
Not supported. |
Supported. |
Supported. |
Supported. |
Supported. |
Supported. |
Not supported. |
Not supported. |
Not supported. |
AnalytiX 10.95 (Released June 2017) |
Not supported. |
Not tested. |
Supported with ICONICS Update 4 or later. |
Supported. |
Supported. |
Supported. |
Service Pack 1. |
Not supported. |
Not supported. |
AnalytiX 10.9 2 (Released October 2015) |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Supported. |
Supported. |
Service Pack 1. |
Not supported. |
Not supported. |
AnalytiX 10.85 2 (Released August 2014) |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Supported. |
Supported. |
Service Pack 1. |
Not supported. |
Not supported. |
AnalytiX 10.81 2 (Released October 2013) |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Supported. |
Service Pack 1. |
Not supported. |
Not supported. |
AnalytiX 10.71 2 (Released October 2012) |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Supported. |
Service Pack 1. |
Not supported. |
Not supported. |
Energy AnalytiX 10.61 2 (Released December 2011) |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Standard, Enterprise or Developer only (NOT Express) |
Not supported. |
Not supported. |
Facility AnalytiX 10.61 2 (Released December 2011) |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Supported. |
Supported. |
Supported. |
1 Notes: The connection to SQL Server data source may be either local or remote. ICONICS supports SQL databases with encryption. Express editions also supported. Earlier versions of SQL Server or other databases are not supported for configuration or logging databases. However, they may be used as data sources in GridWorX Server.
2 Microsoft StreamInsight, a required component for Energy AnalytiX up to and including version 10.9, will run in demo mode for 180 days if not registered with a valid SQL Server license key. This means that SQL Express installations will only be able to run Energy AnalytiX for 180 days unless they are upgraded with a valid SQL Server license key. StreamInsight is no longer required starting in version 10.95.
|
SQL Azure |
SQL Server 2019 |
SQL Server 2017 |
SQL Server 2016 |
SQL Server 2014 |
SQL Server 2012 |
SQL Server 2008 R2 |
SQL Server 2008 |
Earlier versions of SQL Server and Other Databases |
MobileHMI 10.97 (Released March 2021) |
Supported. |
Supported. |
Supported. |
Supported. |
Supported. |
Not tested. |
Not supported. |
Not supported. |
Not supported. |
MobileHMI 10.96.2 (Released November 2020) |
Supported. |
Supported. |
Supported. |
Supported. |
Supported. |
Supported. |
Not supported. |
Not supported. |
Not supported. |
MobileHMI 10.96 & 10.96.1 (Released December 2019 & June 2020) |
Supported. |
Supported. |
Supported. |
Supported. |
Supported. |
Supported. |
Not supported. |
Not supported. |
Not supported. |
MobileHMI 10.95 (Released June 2017) |
Supported. |
Not tested. |
Supported with ICONICS Update 4 or later. |
Supported. |
Supported. |
Supported. |
Service Pack 1. |
Not supported. |
Not supported. |
MobileHMI 10.9 (Released October 2015) |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Supported. |
Supported. |
Service Pack 1. |
Not supported. |
Not supported. |
MobileHMI 10.85 (Released August 2014) |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Supported. |
Supported. |
Service Pack 1. |
Not supported. |
Not supported. |
MobileHMI 10.81 (Released October 2013) |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Supported. |
Service Pack 1. |
Service Pack 2. |
Not supported. |
MobileHMI 10.71 (Released October 2012) |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Supported. |
Service Pack 1. |
Service Pack 2. |
Not supported. |
MobileHMI 10.61 (Released December 2011) |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Supported. |
Supported. |
Not supported. |
1 Notes: The connection to SQL Server data source may be either local or remote. ICONICS supports SQL databases with encryption. Express editions also supported. Earlier versions of SQL Server or other databases are not supported for configuration or logging databases. However, they may be used as data sources in GridWorX Server.
|
SQL Azure |
SQL Server 2019 |
SQL Server 2017 |
SQL Server 2016 |
SQL Server 2014 |
SQL Server 2012 |
SQL Server 2008 R2 |
SQL Server 2008 |
SQL Server 2005 |
Earlier versions of SQL Server |
Other Databases |
GENESIS32 9.6 (Released March 2020) |
Not supported. |
Supported. |
Supported. |
Supported. |
Supported. |
Supported. |
Not tested. |
Not tested. |
Not tested. |
Not supported. |
Microsoft Access.
Oracle 2 8.05 and 9i (using Oracle 9i Client Tools).
TWX32 Logging only: MySQL version 5.0 (using MySQL ODBC Driver version 3.51.09).
|
GENESIS32 9.5 (Released July 2017) |
Not supported. |
Not tested. |
Not tested. |
Supported. |
Supported. |
Supported. |
Supported. |
Supported. |
Supported. |
Not supported. |
|
GENESIS32 9.4 (Released November 2015) |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Supported. |
Supported. |
Supported. |
Supported. |
Supported. |
Not supported. |
|
GENESIS32 9.35 (Released August 2014) |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Supported. |
Supported. |
Supported. |
Supported. |
Supported. |
Not supported. |
|
GENESIS32 9.30 (Released October 2013) |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Supported. |
Supported. |
Supported. |
Supported. |
Not supported. |
|
GENESIS32 9.22 (Released July 2011) |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Supported. |
Supported. |
Supported. |
2000, MSDE, and 7.0. |
|
GENESIS32 9.13 (Released September 2008) |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Supported. |
Supported. |
Supported. |
2000, MSDE, and 7.0. |
|
GENESIS32 9.01 (Released January 2007) |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Supported. |
2000, MSDE, and 7.0. |
1General Note: The Data Mining OPC server can query a larger variety of databases than what is listed in this matrix. This matrix is designed to show the databases that can be used as configuration databases for many of our configurators and as logging databases for TrendWorX32 Logger and AlarmWorX32 Logger, since they are more limited in the databases that can be used. “Not Supported” in this matrix does not necessarily mean that the Data Mining OPC server will be unable to query the database.
2 Note for Oracle: Oracle is only supported for TrendWorX32 and AlarmWorX32 Logging Databases only. We do not allow any version of Oracle to be used as a configuration database. The Oracle Data Connector is required in all versions.
|
SQL Azure |
SQL Server 2019 |
SQL Server 2017 |
SQL Server 2016 |
SQL Server 2014 |
SQL Server 2012 |
SQL Server 2008 R2 |
SQL Server 2008 |
SQL Server 2005 |
Earlier versions of SQL Server |
Other Databases |
GENESIS32 8.05 (Released November 2008) |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Supported. |
2000, MSDE, 6.5, and 7.0. |
Microsoft Access.
Oracle 2 8.0. |
GENESIS32 7.2 (Released January 2005)
|
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
2000, MSDE, 6.5, and 7.0. Data Connector Required 3 |
1General Note: The Data Mining OPC server can query a larger variety of databases than what is listed in this matrix. This matrix is designed to show the databases that can be used as configuration databases for many of our configurators and as logging databases for TrendWorX32 Logger and AlarmWorX32 Logger, since they are more limited in the databases that can be used. “Not Supported” in this matrix does not necessarily mean that the Data Mining OPC server will be unable to query the database.
2 Note for Oracle: Oracle is only supported for TrendWorX32 and AlarmWorX32 Logging Databases only. We do not allow any version of Oracle to be used as a configuration database. The Oracle Data Connector is required in all versions.
3 Data Connector Note: A Data Connection license is required to log to this type of database in this version of GENESIS32. Without this Data Connection license, the logger will only log for two hours.
|
SQL Azure |
SQL Server 2019 |
SQL Server 2017 |
SQL Server 2016 |
SQL Server 2014 |
SQL Server 2012 |
SQL Server 2008 R2 |
SQL Server 2008 |
SQL Server 2005 |
SQL Server 2000 and MSDE |
Other Databases |
BizViz 9.6 (Released March 2020) |
Not supported. |
Supported. |
Supported. |
Supported. |
Supported. |
Supported. |
Not tested. |
Not tested. |
Not tested. |
Not supported. |
Not supported. |
BizViz 9.5 (Released July 2017) |
Not supported. |
Not tested. |
Not tested. |
Supported. |
Supported. |
Supported. |
Supported. |
Supported. |
Supported. |
Not supported. |
Not supported. |
BizViz 9.4 (Released November 2015) |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Supported. |
Supported. |
Supported. |
Supported. |
Supported. |
Not supported. |
Not supported. |
BizViz 9.35 (Released August 2014) |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Supported. |
Supported. |
Supported. |
Supported. |
Supported. |
Not supported. |
Not supported. |
BizViz 9.30 (Released October 2013) |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Supported. |
Supported. |
Supported. |
Supported. |
Not supported. |
Not supported. |
BizViz 9.22 (Released September 2011) |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Supported. |
Supported. |
Supported. |
Supported for all BizViz except Productivity Analytics. |
Not supported. |
BizViz 9.13 (Released November 2008) |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Supported. |
Supported. |
Supported. |
Not supported. |
|
BizViz 9.01 (Released March 2007) |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Supported. |
Supported. |
Not supported. |
BizViz 8.04 (Released December 2006) |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Supported. |
Not supported. |
1 General Note: BridgeWorX and ReportWorX can both query a larger variety of databases than what is listed in this matrix. This matrix is designed to show the databases that can be used as configuration databases for our BizViz products, since they are more limited in the databases that can be used.
|
Windows 10 |
Windows RT |
Windows 8 |
Windows 10 Mobile |
Windows Phone 8 |
Windows Phone 7 |
iOS 1 |
Android 1 |
MobileHMI 10.97 (Released March 2021) |
Fall Creators Update (1809) or later. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Supported. |
Supported. |
MobileHMI 10.96.2 (Released November 2020) |
Fall Creators Update (1809) or later. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Supported. |
Supported. |
MobileHMI 10.96 & 10.96.1 (Released December 2019 & June 2020) |
Fall Creators Update (1809) or later. |
Not supported. |
Not supported. |
Supported. |
Not supported. |
Not supported. |
Supported. |
Supported. |
MobileHMI 10.95 (Released June 2017) |
Anniversary Update (1607) or later. |
Not supported. |
Not supported. |
Supported. |
Not supported. |
Not supported. |
Supported. |
Supported. |
MobileHMI 10.9 (Released October 2015) |
Supported. |
Supported. |
Supported. |
Not tested. |
Supported. |
Not supported. |
Supported. |
Supported. |
MobileHMI 10.85 (Released August 2014) |
Not tested. |
Supported. |
Supported. |
Not tested. |
Supported. |
Not supported. |
Supported. |
Supported. |
MobileHMI 10.81 (Released October 2013) |
Not tested. |
Supported. |
Supported. |
Not tested. |
Supported. |
Not supported. |
Supported. |
Supported. |
MobileHMI 10.71 (Released October 2012) |
Not tested. |
Not supported. |
Not supported. |
Not tested. |
Not supported. |
Supported. |
Not supported. |
Not supported. |
MobileHMI 10.61 (Released December 2011) |
Not tested. |
Not supported. |
Not supported. |
Not tested. |
Not supported. |
Supported. |
Not supported. |
Not supported. |
1 iOS and Android note: The required versions of iOS and Android can be found in the appropriate app store in the app description.
|
SNMP v3 |
SNMP v2 |
SNMP v1 |
GENESIS64 10.97 (Released March 2021) |
Supported. |
Supported. |
Supported. |
GENESIS64 10.96.2 (Released November 2020) |
Supported. |
Supported. |
Supported. |
GENESIS64 10.96 & 10.96.1 (Released December 2019 & June 2020) |
Supported. |
Supported. |
Supported. |
GENESIS64 10.95 (Released June 2017) |
Supported. |
Supported. |
Supported. |
GENESIS64 10.9 (Released October 2015) |
Supported. |
Supported. |
Supported. |
GENESIS64 10.85 (Released August 2014) |
Supported. |
Supported. |
Supported. |
GENESIS64 10.81 (Released October 2013) |
Not supported. |
Supported. |
Supported. |
GENESIS64 10.71 (Released October 2012) |
Not supported. |
Supported. |
Supported. |
GENESIS64 10.61 (Released December 2011) |
Not supported. |
Supported. |
Supported. |
GENESIS64 10.51 (Released December 2010) |
Not supported. |
Supported. |
Supported. |
GENESIS32 9.22 or later (Released July 2011) |
Not supported. |
Supported. |
Supported. |
GENESIS32 9.13 (Released September 2008) |
Not supported. |
Supported. 1 |
Supported. 1 |
GENESIS32 9.01 (Released January 2007) |
Not supported. |
Supported. 1 |
Supported. 1 |
1 Note: The SNMP Configurator in versions 9.13 or earlier can only be configured to use one SNMP version at a time. Most SNMP version 2 devices can use SNMP version 1 to communicate, so if you have a mix of SNMP v1 and v2 devices on your network it’s recommend to configure the SNMP Configurator to use SNMP v1, or upgrade to version 9.2x or later.
|
Chrome |
Edge |
Firefox |
Safari |
Internet Explorer 11 1 |
GENESIS64 10.97 (Released March 2021) |
Supported. |
Supported. |
Supported. |
Supported. |
Not supported. |
GENESIS64 10.96.2 (Released November 2020) |
Supported. |
Supported. |
Supported. |
Supported. |
Limited support. 2 |
GENESIS64 10.96 & 10.96.1 (Released December 2019 & June 2020) |
Supported. |
Supported. |
Supported. |
Supported. |
Limited support. 2 |
GENESIS64 10.95 (Released June 2017) |
Supported. |
Supported. |
Supported. |
Supported. |
Limited support. 2 |
GENESIS64 10.9 (Released October 2015) |
Supported. |
Supported. |
Supported. |
Supported. |
Limited support. 2 |
1 Internet Explorer Microsoft End of Support Note: Starting January of 2016, only the latest Internet Explorer available for an operating system will be supported by Microsoft. For Windows 7 and above, this is Internet Explorer 11. (For more information, see: https://www.microsoft.com/en-us/WindowsForBusiness/End-of-IE-support) If you run into an issue with an ICONICS product, technical support determines that it is specific to the version of the browser, and you are not using a browser supported by Microsoft, then ICONICS may not be able to patch the issue in question.
2 Limited Support Note: Since no version of Internet Explorer is receiving updates (except for certain security updates), Internet Explorer may have performance issues with HTML5 screens. ICONICS recommends using Edge or another HTML5-compliant browser for WebHMI (HTML5) clients.
|
Internet Explorer 11 2 |
Internet Explorer 10 2 |
Internet Explorer 9 2 |
Internet Explorer 8 2 |
Internet Explorer 7 2 |
Other Browsers |
GENESIS64 10.97 (Released March 2021) |
Supported. |
Not tested. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
GENESIS64 10.96.2 (Released November 2020) |
Supported. |
Not tested. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
GENESIS64 10.96 & 10.96.1 (Released December 2019 & June 2020)) |
Supported. |
Supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
GENESIS64 10.95 (Released June 2017) |
Supported. |
Supported. |
Supported. |
Supported. |
Not supported. |
Silverlight Only. |
GENESIS64 10.9 (Released October 2015) |
Supported. |
Supported. |
Supported. |
Supported. |
Not supported. |
Silverlight Only. |
GENESIS64 10.85 (Released August 2014) |
Supported. |
Supported. |
Supported. |
Supported. |
Not supported. |
Silverlight Only. |
GENESIS64 10.81 (Released October 2013) |
Not tested. |
Supported. |
Supported. |
Supported. |
Not supported. |
Silverlight Only. |
GENESIS64 10.71 (Released October 2012) |
Not tested. |
Supported. |
Supported. |
Supported. |
Supported. |
Silverlight Only. |
GENESIS64 10.61 (Released December 2011) |
Not tested. |
Not tested. |
Supported. |
Supported. |
Supported. |
Silverlight Only. |
GENESIS64 10.51 (Released December 2010) |
Not tested. |
Not tested. |
Not tested. |
Supported. |
Supported. |
Silverlight Only. |
1 Silverlight Note: WebHMI Silverlight has been discontinued as of version 10.96.
2 Internet Explorer Microsoft End of Support Note: Starting January of 2016, only the latest Internet Explorer available for an operating system will be supported by Microsoft. For Windows 7 and above, this is Internet Explorer 11. (For more information, see: https://www.microsoft.com/en-us/WindowsForBusiness/End-of-IE-support) If you run into an issue with an ICONICS product, technical support determines that it is specific to the version of the browser, and you are not using a browser supported by Microsoft, then ICONICS may not be able to patch the issue in question.
|
Microsoft Edge |
Internet Explorer 111 |
Internet Explorer 101 |
Internet Explorer 91 |
Internet Explorer 81 2 |
Internet Explorer 71 |
Earlier Internet Explorer Versions and Other Browsers |
WebHMI 9.6 (Released March 2020) |
Not supported. |
Supported in Compatibility View only. |
Not tested. |
Not tested. |
Not tested. |
Not tested. |
Not supported. |
WebHMI 9.5 (Released July 2017) |
Not supported. |
Supported in Compatibility View only. |
Supported. |
Supported. |
Supported. |
Not supported. |
|
WebHMI 9.4 (Released Nov. 2015) |
Not supported. |
Supported. |
Supported. |
Supported. |
Not supported. |
||
WebHMI 9.35 (Released Aug. 2014) |
Not supported. |
Supported. |
Supported. |
Supported. |
Not supported. |
||
WebHMI 9.30 (Released Oct. 2013) |
Not supported. |
Not tested. |
Supported. |
Supported. |
Supported. |
Not supported. |
|
WebHMI 9.22 (Released July 2011) |
Not supported. |
Not tested. |
Supported. |
Supported. |
Supported. |
Internet Explorer 6. |
|
WebHMI 9.13 (Released Sept. 2008) |
Not supported. |
Not tested. |
Not tested. |
Not tested. |
Supported. |
Supported. |
Internet Explorer 6. |
WebHMI 9.01 (Released Jan. 2007) |
Not supported. |
Not tested. |
Not tested. |
Not tested. |
Supported. |
Supported. |
Internet Explorer 6. |
WebHMI 8.05 (Released Nov. 2008) |
Not supported. |
Not tested. |
Not tested. |
Not tested. |
Supported. |
Supported. |
Internet Explorer 6. |
WebHMI 7.2 (Released Jan. 2005) |
Not supported. |
Not tested. |
Not tested. |
Not tested. |
Not tested. |
Not tested. |
Internet Explorer 5.5 and above. Netscape Navigator, with plug-in. |
1 Internet Explorer Microsoft End of Support Note: Starting January of 2016, only the latest Internet Explorer available for an operating system will be supported by Microsoft. For Windows 7 and above, this is Internet Explorer 11. (For more information, see: https://www.microsoft.com/en-us/WindowsForBusiness/End-of-IE-support) If you run into an issue with an ICONICS product, technical support determines that it is specific to the version of the browser, and you are not using a browser supported by Microsoft, then ICONICS may not be able to address the issue in question without requiring a browser upgrade.
2 Note for Internet Explorer v8: Vista or Windows 7 machines being used as WebHMI clients with Internet Explorer v8 must apply this Microsoft patch: http://support.microsoft.com/kb/941833
|
Microsoft Edge |
Internet Explorer 11 2 |
Internet Explorer 10 2 |
Internet Explorer 9 2 |
Internet Explorer 8 2 |
Internet Explorer 7 2 |
Other Browsers |
BizViz 9.6 (Released March 2020) |
Not supported. |
Supported in Compatibility View only. |
Not tested. |
Not tested. |
Not tested. |
Not tested. |
Not supported. |
BizViz 9.5 (Released July 2017) |
Not supported. |
Supported in Compatibility View only. |
Supported in Compatibility View only. |
Supported. |
Supported. |
Supported. |
Not supported. |
BizViz 9.4 (Released November 2015) |
Not supported. |
Supported in Compatibility View only. |
Supported in Compatibility View only. |
Supported. |
Supported. |
Supported. |
Not supported. |
BizViz 9.35 (Released August 2014) |
Not supported. |
Supported in Compatibility View only. |
Supported in Compatibility View only. |
Supported. |
Supported. |
Supported. |
Not supported. |
BizViz 9.30 (Released October 2013) |
Not supported. |
Not tested. |
Supported in Compatibility View only. |
Supported. |
Supported. |
Supported. |
Not supported. |
BizViz 9.22 (Released September 2011) |
Not supported. |
Not tested. |
Supported in Compatibility View only. |
Supported. |
Supported. |
Supported. |
Internet Explorer 6. 2 |
BizViz 9.13 (Released November 2008) |
Not supported. |
Not tested. |
Not tested. |
Not tested. |
Supported. |
Supported. |
Internet Explorer 6. 2 |
BizViz 9.01 (Released March 2007) |
Not supported. |
Not tested. |
Not tested. |
Not tested. |
Not tested. |
Supported. |
Internet Explorer 6. 2 |
BizViz 8.04 (Released December 2006) |
Not supported. |
Not tested. |
Not tested. |
Not tested. |
Not tested. |
Supported. |
Internet Explorer 6. 2. |
1 Note: The 32-bit PortalWorX has been discontinued as of version 9.6.
2 Internet Explorer Microsoft End of Support Note: Starting January of 2016, only the latest Internet Explorer available for an operating system will be supported by Microsoft. For Windows 7 and above, this is Internet Explorer 11. (For more information, see: https://www.microsoft.com/en-us/WindowsForBusiness/End-of-IE-support) If you run into an issue with an ICONICS product, technical support determines that it is specific to the version of the browser, and you are not using a browser supported by Microsoft, then ICONICS may not be able to patch the issue in question.
ICONICS software requires the listed version of Microsoft .NET Framework.
GENESIS64, Hyper Historian, AnalytiX, or MobileHMI |
Microsoft .NET Framework |
|
GENESIS64, Hyper Historian, AnalytiX, or MobileHMI |
Microsoft .NET Framework |
10.97 |
4.7.2 |
|
10.81 |
4.5 |
10.96 - 10.96.2 |
4.7.2 |
|
10.71 |
4.0 |
10.95 |
4.6.2 |
|
10.61 |
4.0 |
10.9 |
4.5 |
|
10.51 |
3.5 SP1 |
10.85 |
4.5 |
|
|
Azure AD |
AD LDS |
2016 |
2012 R2 |
2012 |
2008 R2 |
Security Server 10.97 (Released March 2021) |
Supported. |
Supported. |
Supported. |
Not tested. |
Not tested. |
Supported |
Security Server 10.96.2 (Released November 2020) |
Supported. |
Supported. |
Supported. |
Not tested. |
Not tested. |
Supported |
Security Server 10.96 & 10.96.1 (Released December 2019 & June 2020) |
Supported. |
Supported. |
Supported. |
Not tested. |
Not tested. |
Supported. |
Security Server 10.95 (Released June 2017) |
Not supported. |
Supported. |
Supported. |
Not tested. |
Not tested. |
Supported. |
Security Server 10.9 (Released October 2015) |
Not supported. |
Supported. |
Not tested. |
Not tested. |
Not tested. |
Supported. |
Security Server 10.85 (Released August 2014) |
Not supported. |
Supported. |
Not tested. |
Not tested. |
Not tested. |
Supported. |
Security Server 10.81 (Released October 2013) |
Not supported. |
Supported. |
Not tested. |
Not tested. |
Not tested. |
Supported. |
1 Note: It is possible to have a separate active directory services version than operating system version. For example, it’s possible to run a 2012 R2 server with 2008 R2 directory services.
|
SharePoint 2013 |
SharePoint Server 2010/SharePoint Foundation 2010 |
Microsoft Office SharePoint Server (MOSS) 2007 |
SharePoint Services 3.0 |
SharePoint Services 2.0 |
SharePoint Portal Server 2003 |
PortalWorX-SP 10.95 (Released June 2017) |
Supported. |
Supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
PortalWorX-SP 10.9 (Released October 2015) |
Supported. |
Supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
PortalWorX-SP 10.85 (Released August 2014) |
Supported. |
Supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
PortalWorX-SP 10.81 (Released October 2013) |
Supported. |
Supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
PortalWorX-SP 10.71 (Released October 2012) |
Not supported. |
Supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
PortalWorX64 10.61 (Released December 2011) |
Not supported. |
Supported. |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
PortalWorX 9.5 (Released July 2017) |
Not supported. |
Supported with 2007-compatible rendering. |
Supported. |
Supported. |
Supported. |
Not supported. |
PortalWorX 9.4 (Released November 2015) |
Not supported. |
Supported. |
Supported. |
Supported. |
Not supported. |
|
PortalWorX 9.35 (Released August 2014) |
Not supported. |
Supported. |
Supported. |
Supported. |
Not supported. |
|
PortalWorX 9.30 (Released October 2013) |
Not supported. |
Supported. |
Supported. |
Supported. |
Not supported. |
|
PortalWorX 9.22 (Released September 2011) |
Not supported. |
Supported. |
Supported. |
Supported. |
Not supported. |
|
PortalWorX 9.13 (Released November 2008) |
Not supported. |
Not supported. |
Supported. 2 |
Supported. 2 |
Supported. |
Not supported. |
PortalWorX 9.01 (Released March 2007) |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Supported. |
Not supported. |
PortalWorX 8.04 (Released December 2006) |
Not supported. |
Not supported. |
Not supported. |
Not supported. |
Supported. |
Supported. |
1 Note: The 32-bit PortalWorX has been discontinued as of version 9.6. The 64-bit PortalWorX-SP has been discontinued as of version 10.96.
2 Note: If using 64-bit Windows Server 2008 you must use SharePoint Services 2.0 instead of MOSS 2007 or SharePoint Services 3.0 due to a known issue running in 32-bit compatibility mode on this operating system. This issue does not occur in 32-bit Windows Server 2008, and it has been resolved with version 9.21 or later.
|
Excel 365 |
Excel 2019 |
Excel 2016 |
Excel 2013 |
Excel 2010 |
Excel 2007 |
Excel 2003 |
Earlier Versions |
ReportWorX64 & Express 10.97 (Released March 2021) |
32- and 64-bit. |
32- and 64-bit. |
32- and 64-bit. |
32- and 64-bit. |
Not tested. |
Not supported. |
Not supported. |
Not supported. |
ReportWorX64 & Express 10.96.2 (Released November 2020) |
32- and 64-bit. |
32- and 64-bit. |
32- and 64-bit. |
32- and 64-bit. |
Not tested. |
Not supported. |
Not supported. |
Not supported. |
ReportWorX64 & Express 10.96 & 10.96.1 (Released December 2019 & June 2020) |
32- and 64-bit. |
32- and 64-bit. |
32- and 64-bit. |
32- and 64-bit. |
32- and 64-bit. |
Not supported. |
Not supported. |
Not supported. |
ReportWorX64 & Express 10.95 (Released June 2017) |
Not tested. |
Not tested. |
32- and 64-bit. |
32- and 64-bit. |
32- and 64-bit. |
Not supported. |
Not supported. |
Not supported. |
ReportWorX Express 10.9 (Released October 2015) |
Not tested. |
Not tested. |
32- and 64-bit. |
32- and 64-bit. |
32- and 64-bit. |
Not supported. |
Not supported. |
Not supported. |
ReportWorX Express 10.85 (Released August 2014) |
Not tested. |
Not tested. |
Not tested. |
32- and 64-bit. |
32- and 64-bit. |
Not supported. |
Not supported. |
Not supported. |
|
Excel 365 |
Excel 2019 |
Excel 2016 |
Excel 2013 |
Excel 2010 |
Excel 2007 |
Excel 2003 |
Earlier Versions |
ReportWorX 9.6 (Released March 2020) |
Not tested. |
32-bit only. |
32-bit only. |
32-bit only. |
32-bit only. |
Not tested. |
Not tested. |
Not supported. |
ReportWorX 9.5 (Released July 2017) |
Not tested. |
Not tested. |
32-bit only. |
32-bit only. |
32-bit only. |
Supported. |
Supported. |
Not supported. |
ReportWorX 9.4 (Released November 2015) |
Not tested. |
Not tested. |
32-bit only. |
32-bit only. |
32-bit only. |
Supported. |
Supported. |
Not supported. |
ReportWorX 9.35 (Released August 2014) |
Not tested. |
Not tested. |
Not tested. |
32-bit only. |
32-bit only. |
Supported. |
Supported. |
Not supported. |
ReportWorX 9.30 (Released October 2013) |
Not tested. |
Not tested. |
Not tested. |
32-bit only. |
32-bit only. |
Supported. |
Supported. |
Not supported. |
ReportWorX 9.22 (Released September 2011) |
Not tested. |
Not tested. |
Not tested. |
Not tested. |
32-bit only. |
Supported. |
Supported. |
Not supported. |
ReportWorX 9.13 (Released November 2008) |
Not tested. |
Not tested. |
Not tested. |
Not tested. |
Not tested. |
Supported. |
Supported. |
Excel XP and Excel 2000. |
ReportWorX 9.01 (Released March 2007) |
Not tested. |
Not tested. |
Not tested. |
Not tested. |
Not tested. |
Supported. |
Supported. |
Excel XP and Excel 2000. |
This table describes which versions of ICONICS products can be installed on the same machine because they share a common licensing version. Items on the same row can be installed on the same machine. Items on different rows require different licensing versions so they cannot be installed on the same machine.
GENESIS64, AnalytiX, & Hyper Historian |
GENESIS32 & BizViz |
ICONICS OPC Server Suite by Kepware |
10.972 |
9.602 |
5.5c2 |
10.96 - 10.96.22 |
9.602 |
5.5c 2 |
10.95 |
9.50 |
5.5c |
10.90-10.93 |
9.40 |
5.5b |
10.80-10.87 |
9.30-9.35 |
5.5a |
10.7x |
9.22 (with 9.27 Licensing SP 3) |
5.5 (with 9.27 Licensing SP 3) |
10.6x |
9.22 |
5.5 |
10.5x |
9.20-9.21 |
5.3 |
10.0x |
9.0x-9.1x |
4.3 |
1 General Note: Certain products cannot have both their 32- and 64-bit components installed on the same machine at the same time. These products include: AlarmWorX32 Multimedia/AlarmWorX64 Multimedia, BridgeWorX/BridgeWorX64, and ReportWorX/ReportWorX64.
2 10.97, 10.96 - 10.96.2, 9.6, & 5.5c Note: When 10.96-10.97, 9.6, and 5.5c products are installed on the same system, the 64-bit version of the License Utility must be used to activate all ICONICS licenses, including 5.5c.
39.27 Note: Version 10.7x is only compatible with version 9.22 GENESIS32, 9.22 BizViz, or 5.5 ICONICS OPC Server Suite if the 9.27 Licensing Service Pack is applied. This licensing service pack will be installed automatically by default with 10.7x.
|
Sentinel USB Key (black) |
One-Wire USB Key (blue) |
Parallel Port Key |
GENESIS64, Hyper Historian, AnalytiX, MobileHMI 10.x |
Supported. |
Not supported. |
Not supported. |
GENESIS32 & BizViz 9.22 or later |
Supported. |
Not supported. |
Not supported. |
GENESIS32 & BizViz 9.13 |
Supported. 1 |
Supported. 1 |
Supported. 1 |
GENESIS32 & BizViz 9.01 |
Supported. 1 |
Supported. 1 |
Supported. 1 |
GENESIS32 & BizViz 8.05 |
Supported. |
Supported. |
Supported. |
GENESIS32 & BizViz 8.04 or earlier |
Not supported. |
Supported. |
Supported. |
1 Note for GENESIS32 & BizViz 9.1x and 9.0x: ICONICS recommends installing the 9.14 Licensing Service Pack to any 9.1x or 9.0x system. Some 9.0x or 9.1x versions will not support all hardware key types unless the 9.14 Licensing Service Pack has been applied.